Sign In | Join Free | My udpf.com |
|
Categories | Security Alarm Device |
---|---|
Model Number: | APX-101 |
Place of Origin: | China |
Brand Name: | ALEPH |
Certification: | CE ISO |
MOQ: | Negotiation |
Price: | Negotiable |
Packaging Details: | Packaging Details:gift box/color box packaging or according t |
Delivery Time: | 25-30 days |
Payment Terms: | TT IN ADVANCE |
Name: | Pir Motion Sensor Ceiling Mounted |
Installation Way: | Wall Mounted |
Current Drain: | 25mA(max.) at 12VDC |
Detection Range: | 40ft x 56ft (12mx17m) |
Input Voltage: | 10 ~ 16VDC |
Pyro Type: | Dual Element |
Environmental: | 95% max. |
Weight: | 3.0 oz (83.5g) |
Dimensions: | 3.9"Hx2.5"Wx1.7"D (98.0x64.0x43.0mm) |
Mounting Height: | 6.5 ~ 8.5 ft (2~2.6m) |
High Efficiency Security Alarm Device Pir Motion Sensor Ceiling
Mounted
APX-101 (Wide-angle) Detection Range: 12m×14m
Pir Motion Sensor Ceiling Mounted Description:
The ALEPH APX series sensors provide a wall mount detection solution in a ceiling mount detector package. Model APX-101 provide a standard wide angle detection area, while the APX-201 views a long range / narrow width pattern. Packaged in a uni-spherical housing the APX models offer a simple method to conceal security coverage. With selectable Pulse Count and Sensitivity adjustments the APX series allows absolute detection in an unintaisive package.
Pir Motion Sensor Ceiling Mounted Introduction
Item | Specification | |
Model | APX-101 | APX-201 |
Detection Range | 40ftx46ft (12m×14m) | 65ftx6ft (20m×2m) |
Supply Voltage | 9 ~ 28V DC (Non-polar) | |
Current Draw | Max. 22mA at 12V DC | |
Detection Method | Passive Infrared | |
Vertical Adjustment | 0 ~ 12° | |
Horizontal Adjustment | ±10° | |
Warm-up Time | Approx. 60S | |
Alarm Output | N.C., 30VDC, 0.3A Max. | |
Alarm Period | Approx. 2S | |
Exception Detection | The supply voltage is lower than the normal voltage / the circuit is abnormal: continuously LED on | |
Alarm Memory Indicator | Orange LED (Intrusion alarm 3 minutes later, keeping on lighting 47 minutes) | |
Alarm Indicator | Red LED (On/Off Selectable) | |
Sensitivity Adjustment | Standard / Low sensitivity | |
Pulse Count | 2 or 4, Selectable | 2 pulses |
Pet immune | When sensitivity adjusting to low sensitivity ,pet immune | None |
Installation Location | Indoor ceiling | |
Operating Environment | -20℃ ~ +50℃, Rh.95% Max. | |
Wiring Mode | Terminal | |
Appearance | Main body: ABS resin, Cover: PE resin (milk white) | |
Dimensions | Φ149×55mm | |
Weight | 200g |
Pir Motion Sensor Ceiling Mounted Features
Installation: Determine the mounting location which provides desired coverage
area. For correct detection a level ceiling is required. Measure
the ceiling to floor distance. To begin installation process,
separate the base assembly from the detector head by sliding the
base lock lever away from the base and rotating the detector head
counter-clockwise to the short mark on the base. When rotation
movement is complete, head away from the base.
Both APX models require a 10.5 to 28 VOC power source Power
terminals include reverse polarity protection. Maximum current draw
is 22mA. Use 18-24 gauge non-shielded. four conductor wire material
lor all wiring connections (Refer to Pg 2 for further info). Do not
run APX wire parallel to existing AC wiring. For UL installations,
all wiring must be in accordance with NEC, NPFA 70 standards.
After wiring is ready mount base to ceiling, using supplied mount
points. Complete wiring to the appropriate base terminals (see
illustration on page two for additional details).
Prior to re-attaching sensor head to the base set mirror optics
vertical adjustment on detector head assembly to match coverage
area to mounting height. Make appropriate configuration settings to
Pet immunity Select / Sensitivity Adjustment (Switch 1). Pulse
Count (PC) Setting (Switch 2), and Alarm Memory / Alarm LEO
configuration (Switches 3 & 4 respeclively). PC fixed at 2 on APX-201.
Note: Pet immunity Characteristics have not been evaluated by
Underwriters Laboratories.
A Standard Sensitivity setting lowers the alarm threshold level
required for a detection event. Pet immunity features are only
available with a sensitivity setting of Low / Pet lmmunity. Pet
Immunity features apply W APX-101 only The PC delermines the number
of detection events ® required prior to an alarm event being
signaled. The APX-201 Pulse Count is fixed at 2 pulses. Enabling
the Alarm LED allows a momentary soiid ^ted LED indication after an
alarm event is recorded.
Caution: The APX models are for indoor use only, do not mount in open or
outdoor areas.
Avoid installations where the detector directly views heating,
cooling, sun or automobile headlight sources.
Do not mount in areas where water or oil vapors are present.
Avoid mounting so that screens or curtains are blocking the
detector's field of view.
![]() |