Brand Name: CHINT
Model Number: CU/XLPE/PVC POWER CABLE
Certification: KEMA/CE/SGS
Place of Origin: CHINA
MOQ: Negotiable
Price: Negotiable
Supply Ability: 1000KM/Month
Packaging Details: iron with wooden or wood or iron
Conductor: class 1or 2
Insulation: XLPE
Filler: PP material
Conductor size: 1.5~630mm2
Marking: embossing or printing
Package: iron with wooden or wood or iron
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

PVC Sheathed Copper Power Cable Low Voltage XLPE Insulated Cable 1 - 5 Core

PVC Sheathed Copper Power Cable Low Voltage XLPE Insulated Cable 1 - 5 Core


Standards

International: IEC 60502.1, IEC 60228

China: GB/T 12706.1-2008

Other standards such as BS,VDE and ICEA upon request


Technical data

Rated voltage: 0.6/1kV

Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.

Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃

Min. Bending Radius: single core cable 20(d+D)±5%

Multi-core cable 15(d+D)±5%


Detailed Product Description

Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with IEC 60228

Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃

Sheath : PVC type ST2 , according to IEC 60502, black


Note:

Insulation identification as per standards or customer requirement


Applications

For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.


Certificates

CE, SGS, KEMA and more others at request


Technical Specifications


Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulation ThicknessSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×1.51/1.380.71.45.64312.13.52633
1×2.51/1.760.71.46.0547.563.53443
1×41/2.230.71.46.4714.613.54456
1×61/2.740.71.47.0933.083.55670
1×107/1.330.71.48.21371.833.57794
1×167/1.670.71.49.21951.153.5100120
1×257/2.100.91.410.92920.7273.5130155
1×357/2.480.91.412.03890.5243.5160185
1×5010/2.561.01.413.25140.3873.5195220
1×7014/2.561.11.415.17160.2683.5245270
1×9519/2.561.11.516.99690.1933.5300320
1×12024/2.561.21.518.61,2030.1533.5349365
1×15030/2.561.41.620.61,4790.1243.5400410
1×18537/2.561.61.622.71,8530.09913.5465465
1×24048/2.581.71.725.32,4080.07543.5550540
1×30060/2.581.81.827.92,9880.06013.5635610
1×40060/2.932.01.931.53,8600.0473.5745695
1×50060/3.332.2235.24,8400.03663.5860780
1×63060/3.762.42.239.46,1820.02833.5990880
2×1.51/1.380.71.89.510612.13.52031
2×2.51/1.760.71.810.31337.563.52741
2×41/2.230.71.811.21724.613.53553
2×61/2.740.71.812.22213.083.54566
2×107/1.330.71.814.73281.833.56390
2×167/1.670.71.816.74601.153.584117
2×257/2.100.91.820.16830.7273.5113151
2×357/2.480.91.822.49000.5243.5139181
2×5010/2.561.01.819.01,0370.3873.5161210
2×7014/2.561.11.821.81,4460.2683.5204257
2×9519/2.561.1224.71,9670.1933.5252310
2×12024/2.561.22.127.12,4440.1533.5291351
2×15030/2.561.42.230.33,0080.1243.5333393
2×18537/2.561.62.333.53,7720.09913.5385445
2×24048/2.561.72.537.74,9090.07543.5457516
2×30060/2.561.82.741.46,0900.06013.5527583
3×1.51/1.380.71.89.912712.13.52031
3×2.51/1.760.71.810.71637.563.52741
3×41/2.230.71.811.82164.613.53553
3×61/2.740.71.812.92853.083.54566
3×107/1.330.71.815.64291.833.56390
3×167/1.670.71.817.76131.153.584117
3×257/2.100.91.821.49230.7273.5113151
3×357/2.480.91.823.81,2290.5243.5139181
3×5010/2.561.01.822.51,5170.3873.5161210
3×7014/2.561.11.926.12,1330.2683.5204257
3×9519/2.561.1229.32,8910.1933.5252310
3×12024/2.561.22.132.33,6000.1533.5291351
3×15030/2.561.42.336.14,4400.1243.5333393
3×18537/2.561.62.440.15,5790.09913.5385445
3×24048/2.561.72.645.57,2880.07543.5457516
3×30060/2.561.82.850.09,0450.06013.5527583
4×1.51/1.380.71.810.715212.13.52031
4×2.51/1.760.71.811.61997.563.52741
4×41/2.230.71.812.72674.613.53553
4×61/2.740.71.813.93563.083.54566
4×107/1.330.71.817.05421.833.56390
4×167/1.670.71.819.47821.153.584117
4×257/2.100.91.823.51,1850.7273.5113151
4×357/2.480.91.826.31,5860.5243.5139181
4×5010/2.561.01.925.51,9990.3873.5161210
4×7014/2.561.1229.42,8100.2683.5204257
4×9519/2.561.12.133.53,8230.1933.5252310
4×12024/2.561.22.337.24,7830.1533.5291351
4×15030/2.561.42.441.35,8790.1243.5333393
4×18537/2.561.62.646.57,4340.09913.5385445
4×24048/2.561.72.852.79,7010.07543.5457516
4×30060/2.561.8357.912,0300.06013.5527583
5×1.51/1.380.71.811.517912.13.52031
5×2.51/1.760.71.812.52367.563.52741
5×41/2.230.71.813.83214.613.53553
5×61/2.740.71.815.24303.083.54566
5×107/1.330.71.818.66591.833.56390
5×167/1.670.71.821.39571.153.584117
5×257/2.100.91.825.91,4560.7273.5113151
5×357/2.480.91.828.91,9550.5243.5139181
5×5019/1.861.0228.92,5020.3873.5161210
5×7014/2.561.12.133.63,5250.2683.5204257
5×9519/2.561.12.338.24,7980.1933.5252310
5×12024/2.561.22.442.35,9900.1533.5291351
5×15030/2.561.42.647.37,3930.1243.5333393
5×18537/2.561.62.852.69,3120.09913.5385445
5×24048/2.561.7359.512,1370.07543.5457516
5×30060/2.561.83.265.615,0640.06013.5527583
3×2.5+1×1.51/1.760.71.811.31877.563.52741
3×4+1×2.51/2.230.71.812.42504.613.53553
3×6+1×41/2.740.71.813.63343.083.54566
3×10+1×67/1.330.71.816.24941.833.56390
3×16+1×107/1.670.71.818.87211.153.584117
3×25+1×167/2.100.91.822.51,0830.7273.5113151
3×35+1×167/2.480.91.824.61,3820.5243.5139181
3×50+1×2510/2.561.01.824.91,7870.3873.5161210
3×70+1×3514/2.561.11.929.22,5150.2683.5204257
3×95+1×5019/2.561.12.133.23,4210.1933.5252310
3×120+1×7024/2.561.22.236.84,3390.1533.5291351
3×150+1×7030/2.561.42.340.45,1800.1243.5333393
3×185+1×9537/2.561.62.545.56,6210.09913.5385445
3×240+1×12048/2.561.72.751.18,5670.07543.5457516
3×300+1×15060/2.561.82.956.510,6240.06013.5527583
3×2.5+2×1.51/1.760.71.812.12137.563.52741
3×4+2×2.51/2.230.71.813.32874.613.53553
3×6+2×41/2.740.71.814.63863.083.54566
3×10+2×67/1.330.71.817.25661.833.56390
3×16+2×107/1.670.71.820.28371.153.584117
3×25+2×167/2.100.91.824.01,2540.7273.5113151
3×35+2×167/2.480.91.825.91,5500.5243.5139181
3×50+2×2510/2.561.01.926.22,0400.3873.5161210
3×70+2×3514/2.561.1230.22,8520.2683.5204257
3×95+2×5019/2.561.12.234.33,8740.1933.5252310
3×120+2×7024/2.561.22.337.94,9700.1533.5291351
3×150+2×7030/2.561.42.442.35,8490.1243.5333393
3×185+2×9537/2.561.62.647.77,5330.09913.5385445
3×240+2×12048/2.561.72.853.69,7150.07543.5457516
3×300+2×15060/2.561.8359.712,0570.06013.5527583
4×2.5+1×1.51/1.760.71.812.32257.563.52741
4×4+1×2.51/2.230.71.813.63044.613.53553
4×6+1×41/2.740.71.814.94083.083.54566
4×10+1×67/1.330.71.817.96121.833.56390
4×16+1×107/1.670.71.820.78971.153.584117
4×25+1×167/2.100.91.824.91,3550.7273.5113151
4×35+1×167/2.480.91.827.41,7520.5243.5139181
4×50+1×2510/2.561.01.926.62,2410.3873.5161210
4×70+1×3514/2.561.12.130.83,1590.2683.5204257
4×95+1×5019/2.561.12.234.74,2780.1933.5252310
4×120+1×7024/2.561.22.438.75,4310.1533.5291351
4×150+1×7030/2.561.42.543.56,5710.1243.5333393
4×185+1×9537/2.561.62.748.38,3400.09913.5385445
4×240+1×12048/2.561.72.954.910,8380.07543.5457516
4×300+1×15060/2.561.83.160.613,4430.06013.5527583

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

Armored or unarmored. If armor, the armor type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement


PACKING AND SHIPPING

We are capable of meeting the strictest delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.


Product Photo

Cheap PVC Sheathed Copper Power Cable Low Voltage XLPE Insulated Cable 1 - 5 Core for sale
Send your message to this supplier
 
*From:
*To: Zhejiang CHINT Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0