| Sign In | Join Free | My udpf.com |
|
| Categories | Bagging Controller |
|---|---|
| Brand Name: | Supmeter |
| Model Number: | BST106-M10[AL] |
| Certification: | CE |
| Place of Origin: | China |
| MOQ: | 1pcs |
| Price: | Negotiation |
| Payment Terms: | L/C, T/T, Western Union |
| Supply Ability: | 3000pcs/month |
| Delivery Time: | 3-10 working days |
| Packaging Details: | 1pcs/box |
| Power Supply: | DC24V±20% |
| Max. Connect: | 16Loadcells[350Ω] |
| Input: | 9DIs |
| Output: | 18DOs |
| COM@COM1: | RS232 |
| COM2: | RS485 |
| Packing Accuracy: | 0.2%-0.5% |
| Accuracy grade: | III |
High-accuracy 0.2% Bagging Weighing Packaging Controller
Main Features:
User Login Interface:
| Name | Operation | Note |
| 【Login】 | User Login. Exfactory Passwords:
| Operation ‘Main Menu / F5 User / Password / PSW Set’ for Modifying Password. |
| 【User Name】 | After password inputted, the matching User Name will be displayed. |
|
| 【Operate】 | Enter ‘Main User Interface’. | Operation ‘Main Menu / F5 User / Password / Login [Logoff]’ for Re-login and Logoff. |
1-Bucket Scale & 1-Bag Scale:

Loss-in-weight Scale:

Button Operation:
| Name | Operation | State Indicator | Authorization |
| 【Auto】 | Auto / Manual [Emergency Stop] switch. | Green: Auto state. Grey: Manual state. | All Users |
| 【Start】 | Start. | Green: Running state. Grey: Stop state. | |
| 【Re-run】 | Clear Alarm & Recover Running. | ||
| 【Stop】 | Normal Stop [Last Batch]. Stop after the present batch finished. | Flashing Red. | |
| 【E-Stop】 | Emergency Stop. | ||
| 【Alarm】 | Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after alarms cleared. | Red: Alarm state. | |
| 【Print】 | Report Print:
| ||
| 【Lock】 | Screen-locking: Locking/unlocking the operating buttons of main user interface. Auto Screen-locking: Refer to parameter [901]. | Flashing Red: Locked. Grey: Unlocked. | |
| 【Menu】 | Enter Main Menu. | ||
| 【User】 | User Login. Display: Operator / Engineer / Admin. | ||
| 【Zero】 | Manual Zero [No Power-down Protection]. | Flashing green. | |
| 【Bag】 | Bag-clamp/release Request. | Green: Bag-clamping state. Grey: Bag-releasing state. | |
| 【Bulk】 | Manual Start/Stop Bulk Feed. | Green: Working state. | |
| 【Med】 | Manual Start/Stop Medium Feed. | ||
| 【Drip】 | Manual Start/Stop Dribble Feed. | ||
| 【Dump】 | Manual Start/Stop Dumping. | ||
| 【Mat.】 | Manual Start/Stop Supplying Materials into Feeding Bin. | Flashing green. | |
| 【Clear】 | Clear Screen: Clear the display values of Feeding Weight, Totalized Weight, Batch Count and Cycle Speed. | Engineer Administrator |
Feild Installation:



|