75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers

Categories Precision Air Conditioning Units
Brand Name: Coolent
Model Number: CYAT76-90
Certification: ISO/CE
Place of Origin: China
MOQ: 1
Price: to be Negotiated
Payment Terms: T/T
Supply Ability: 1000/Month
Delivery Time: 4W
Packaging Details: WOODEN
Cooling: 75-90KW
Product Mounting: Floor Standing
Condition: Full New
Type: Precision air conditioning unit( air cooled )
Operating voltage: 380/400 VAC,230 VAC,220V
Warranty: 1 Year(12month)
Product name: Precision air conditioning units
Refrigerant: R22(R407C/R410A)
Application: Computer Room/Printing factory/Office/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Color: Black/Grey/White/Other custom colors
Airflow: Down Flow/Front flow
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers

75KW Capacity Precision Air Cooling Units For Test Rooms Data Centers


Product Introduction

Coolnet server air conditioners series can be used in precision environmental adjustments in big, small and medium computer rooms, battery rooms, equipment rooms and other places. The unit adopts advanced design concepts with strictly tested by precision air-conditioning professional laboratories. It has high efficiency, energy saving, stability and long life. It has operating characteristics, and has constant temperature and humidity adjustment functions, which can meet the precise environmental adjustment needs of different industries such as IT, electric power, finance, medical laboratories and transportation.


Benefits


Applications

    • Computer room and data center
    • Switch room and mobile center station in telecommunication
    • High-tech environment and lab
    • Industrial automation control room and precision manufacturing workshop
    • Standard test room and calibration center
    • UPS and battery room
    • Test room in hospital
    • Biochemical culture chamber

    Technical Features


    High sensible heat
    The host and peripherals, servers, switches, optical transceivers and other computer equipment installed in the computer room, as well as power support equipment, such as UPS power supply, will dissipate heat into the computer room by means of heat transfer, convection, and radiation. These heat only cause the temperature in the computer room. The increase is sensible heat. The heat dissipation of a server cabinet ranges from a few kilowatts to a dozen kilowatts per hour. If a blade server is installed, the heat dissipation will be higher. The heat dissipation of large and medium-sized computer room equipment is about 400W/m2, and the data center with higher installed density may reach more than 600W/m2. The sensible heat ratio in the computer room can be as high as 95%.


    Low latent heat
    It does not change the temperature in the computer room, but only changes the moisture content of the air in the computer room. This part of the heat is called latent heat. There is no humidity dissipation device in the computer room, and the latent heat mainly comes from the staff and the outdoor air, while the large and medium-sized computer room generally adopts the management mode of man-machine separation. Therefore, the latent heat in the engine room is small.


    Uninterrupted operation, year-round cooling
    The heat dissipation of the equipment in the computer room is a steady heat source and operates uninterrupted throughout the year. This requires a set of uninterrupted air conditioning guarantee system, and there are also high requirements on the power supply of the air conditioning equipment. And for the air-conditioning system that protects important computer equipment, there should also be a generator set as a backup power supply. The long-term steady-state heat source causes the need for cooling even in winter, especially in the southern region. In the northern region, if cooling is still required in winter, the condensing pressure of the unit and other related issues need to be considered when selecting an air-conditioning unit. In addition, the proportion of outdoor cold air intake can be increased to achieve the purpose of energy saving.


    Technical Parameters


    Model: CYAT26D/UT31D/UT35D/UT41D/UT45D/UT50D/UT55D/UT61D/UT70D/UT76D/UT85D/UT90D/UT100D/U
    Power Supply380V 3Ph-50HZ
    Air DischargeUpflow/Downflow
    Cooling Capacity :24℃/50%RH
    Total Capacity (1)KW26.931.935.941.945.350.555.461.470.576.285.590.8102
    SensibleKW24.829.533.138.842.547.851.657.565.271.279.584.595.7
    AEERW/W3.63.63.63.63.63.73.73.63.63.63.63.63.6
    Air Flowm3/h800095001000011500130001550016000175001850020500225002350024200
    Compressor Hermetic scroll
    RefrigerantR407C
    Compressor quantityPC2222222222222
    Fan Section Centrifugal fan (Optional EC)
    Fan quantityPC2222222223333
    Rated currentA4.34.34.34.44.44.455.25.26.516.516.516.5
    Rated powerW1600160018001800200020003000330039003900540063006300
    Total heating capacityKW66699999912121212
    MaterialPTC
    Humidifier Section Electrode type
    CapacityKg/h5555131313131313131313
    Rated CurrentA6666151515151515151515
    Condenser Model2*582*582*582*582*802*802*1002*1002*1202*1502*1502*1652*180