Sign In | Join Free | My udpf.com |
|
Categories | Laser Gas Analyser |
---|---|
Brand Name: | ESEGAS |
Model Number: | ESE-LASER-100 |
MOQ: | 1 unit |
Payment Terms: | T/T |
Delivery Time: | 14 working days |
Name: | Environmental Monitoring Laser Gas Analyser |
Response time (T90): | ≤30s |
Analog output: | 4-20mA output (isolation, maximum load 750Ω) |
Digital communication: | RS485/RS232/GPRS |
Power: | 100VAC ~ 240VAC |
Repeatability: | ≤1% |
Principle: | Tunable Diode Laser Absorption Spectroscopy (TDLAS) Technology |
Laser Gas Analysis TDLAS Technology 19 Inch NH3/HCL/HF/H2S/CO/CO2/O2
Laser gas analysis is a technique for measuring the composition of a gas sample. It uses a laser to excite the molecules in the sample, and then measures the amount of light that is emitted by the molecules. The amount of light that is emitted depends on the type of molecule, so this information can be used to determine the composition of the sample.
Laser gas analysis is used in a variety of applications, including:
- Industrial process control
- Environmental monitoring
- Medical diagnostics
- Research and development
Laser gas analysis is a versatile technique that can be used to
measure a wide range of gases. It is also a relatively fast and
accurate technique, and it can be used to measure gases in a
variety of environments.
Here are some of the benefits of using laser gas analysis:
- It is a fast and accurate technique.
- It can be used to measure a wide range of gases.
- It can be used in a variety of environments.
- It is a versatile technique that can be used for a variety of
applications.
Laser gas analysis is a valuable tool that can be used to measure
the composition of gas samples. It is a fast, accurate, and
versatile technique that can be used in a variety of applications.
ESE-LASER-200 Laser Gas Analyser is a 19" 4U TDLAS gas analyzer for industrial online analysis .The gas analyzer combine multiple reflection long optical path technology that can analysis gas including NH3,HCL,HF,CH4,H2S,CO,CO2,O2 .
Specifiications
Linearity Error | ≤±1%FS |
Repeatability | ≤±1% |
Zero Drift | ≤±1%FS/half year |
Span Drift | ≤±1%FS/half year |
Calibration Cycle | ≤2 times/year |
Response time | ≤30S |
Interface Signal | |
Analog Output | 2*4-20mA output |
Analog Input | 2*4-20mA output |
Digital Output | RS485/RS232/GPRS |
Relay Output | 3(24V,1A) |
Operating Conditions | |
Power Supply | 100VAC-240VAC |
Purge Gas | 0.3Mpa-0.8Mpa |
Ambient Temperature | ’-20℃-+60℃ |
![]() |