Sign In | Join Free | My udpf.com |
|
Categories | 1140v Soft Starter |
---|---|
Brand Name: | Anchorwill |
Model Number: | AKS620 |
Certification: | 3C |
Place of Origin: | China |
MOQ: | 1 |
Payment Terms: | L/C,T/T |
Delivery Time: | 1 - 10 |
Packaging Details: | Packing in wooden cases for export |
Applicable standards: | GB14048.6-2008(idt IEC 60947-4-2:2002) |
Motor power: | 18A-1000A(4-500kW) |
Key lock and function selection: | Partial or full locking of keys, define the function range of some keys to prevent misuse. |
Protection and monitoring: | Short-circuit, over-voltage, under-voltage, overload, phase failure, phase sequence, over-current, grounding, current imbalance Motor temperature protection, repeat start time |
Adjustable starting torque: | 30%-80%(direct starting torque) |
Number of functions: | >145 |
Company Info. |
Suzhou ANCHORWILL Technology Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
AKS620 Mining Low Voltage Soft Starter 1140V Soft Starter
Product Overview
The starter is suitable for coal mines containing explosive gas (A-burning) and coal dust, and is used for remote control of soft starting, stopping and reversing or stopping in place of the corresponding frequency and voltage of mining explosion-proof three-phase squirrel-cage asynchronous motors in normal operation to provide comprehensive protection for the motor and its wiring, and it has the advantages of small starting current, balanced and reliable starting speed, no vibration of the start-up process tape, and small impact on the power grid.
Product Key Features
Leakage lockout
Built-in leakage detection function, using additional: DC way to detect leakage, without the need for external leakage plug-in.
Bypass monitoring
Whether it is a direct start or soft start state, it plays a real-time monitoring function, more comprehensive protection of the motor.
Communication function
Standard configuration of communication components, support for customization, a variety of standard bus protocols, easy to realize group control technology, factory default Modbus-R Tu protocol.
![]() |